{"id":11016,"date":"2022-04-05T08:00:00","date_gmt":"2022-04-05T13:00:00","guid":{"rendered":"https:\/\/blog.misumiusa.com\/?p=11016"},"modified":"2022-03-30T13:55:12","modified_gmt":"2022-03-30T18:55:12","slug":"how-to-choose-the-right-rj45-cables","status":"publish","type":"post","link":"https:\/\/us.misumi-ec.com\/blog\/how-to-choose-the-right-rj45-cables\/","title":{"rendered":"How to Choose the Right RJ45 Cables"},"content":{"rendered":"\n<p>Very commonly used in homes and offices, RJ45 cables are probably one of the most familiar cables to you. However, many of you may be puzzled by words such as Cat5e, Cat6A, UTP, and STP that you do not often hear when you try to select them. In this article, I will show you how to choose the right RJ45 cable for your environment.<\/p>\n\n\n\n<h3>1. Choose by Category<\/h3>\n\n\n\n<p>RJ45 cables are divided into categories based mainly on maximum transmission speed and maximum bandwidth. The higher the category (category with higher numbers), the faster the transmission speed and bandwidth. It is recommended to select a cable according to the recommended category of the connected device, but it is also possible to use a cable with a category higher than the recommended category of the connected device.<\/p>\n\n\n\n<p>For example, if the recommended category of the device is &#8220;CAT5e&#8221;, then &#8220;CAT6&#8221; or higher can also be used.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-1-Cable-Categories-RJ45-Cables.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" width=\"536\" height=\"302\" src=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-1-Cable-Categories-RJ45-Cables.jpg\" alt=\"\" class=\"wp-image-11017\" srcset=\"https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-1-Cable-Categories-RJ45-Cables.jpg 536w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-1-Cable-Categories-RJ45-Cables-300x169.jpg 300w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-1-Cable-Categories-RJ45-Cables-150x85.jpg 150w\" sizes=\"(max-width: 536px) 100vw, 536px\" \/><\/a><figcaption>Table 1: Cable Categories<\/figcaption><\/figure><\/div>\n\n\n\n<p>More detailed information can be found in this article: <a href=\"https:\/\/us.misumi-ec.com\/blog\/how-to-choose-between-cat-5-cat-5e-and-cat-6-cables\/\" target=\"_blank\" rel=\"noreferrer noopener\">How to Choose Between Cat 5, Cat 5e and Cat 6 Cables<\/a><\/p>\n\n\n\n<h3>2. Choose by Shield Structures<\/h3>\n\n\n\n<p>There are two types of RJ45 cables, STP and UTP, depending on whether they are shielded or not.<\/p>\n\n\n\n<p>\u3000UTP: Unshielded Twist Pair&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p>\u3000STP: Shielded Twist Pair<\/p>\n\n\n\n<p>Shielding is used to protect cable wiring from noise (electromagnetic leakage and interference). Shielded cables are recommended in environments such as factories where a lot of noise is generated.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-2-UTP-and-STP-RJ45-Cables.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" width=\"769\" height=\"93\" src=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-2-UTP-and-STP-RJ45-Cables.jpg\" alt=\"\" class=\"wp-image-11018\" srcset=\"https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-2-UTP-and-STP-RJ45-Cables.jpg 769w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-2-UTP-and-STP-RJ45-Cables-300x36.jpg 300w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-2-UTP-and-STP-RJ45-Cables-150x18.jpg 150w\" sizes=\"(max-width: 769px) 100vw, 769px\" \/><\/a><figcaption>Table 2: Shield Structures<\/figcaption><\/figure><\/div>\n\n\n\n<p>More detailed information on shielded cables can be found in this article: <a href=\"https:\/\/us.misumi-ec.com\/blog\/to-shield-or-not-to-shield-cables\/\" target=\"_blank\" rel=\"noreferrer noopener\">To Shield or Not to Shield \u2013 Cables<\/a><\/p>\n\n\n\n<h3>3. Choose by Length<\/h3>\n\n\n\n<p>Solid Wires are recommended for long-distance transmission (up to 100 meters), and Stranded Wires for short-distance transmission (up to 15 meters).<\/p>\n\n\n\n<p>Solid wires have a single conductor, whereas stranded wires are made by twisting thin conductors together. Solid wires are slightly stiffer but are more stable for long-distance transmission.<\/p>\n\n\n\n<p>Stranded cables are soft and easy to handle, making them suitable for wiring in small spaces, but they tend to be unstable for long-distance transmission.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-3-Wire-Length-RJ45-Cables.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" width=\"766\" height=\"115\" src=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/Table-3-Wire-Length-RJ45-Cables.jpg\" alt=\"\" class=\"wp-image-11019\" srcset=\"https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-3-Wire-Length-RJ45-Cables.jpg 766w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-3-Wire-Length-RJ45-Cables-300x45.jpg 300w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/Table-3-Wire-Length-RJ45-Cables-150x23.jpg 150w\" sizes=\"(max-width: 766px) 100vw, 766px\" \/><\/a><figcaption>Table 3: Wire Length<\/figcaption><\/figure><\/div>\n\n\n\n<p>These are the three most important factors in selecting an RJ45 cable. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/us.misumi-ec.com\/vona2\/detail\/110400653940\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" src=\"https:\/\/blog.misumiusa.com\/wp-content\/uploads\/2022\/03\/RJ45-Cables.jpg\" alt=\"\" class=\"wp-image-11020\" width=\"423\" height=\"423\" srcset=\"https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/RJ45-Cables.jpg 1000w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/RJ45-Cables-300x300.jpg 300w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/RJ45-Cables-150x150.jpg 150w, https:\/\/us.misumi-ec.com\/blog\/wp-content\/uploads\/2022\/03\/RJ45-Cables-768x768.jpg 768w\" sizes=\"(max-width: 423px) 100vw, 423px\" \/><\/a><figcaption><a href=\"https:\/\/us.misumi-ec.com\/vona2\/detail\/110400653940\/\" target=\"_blank\" rel=\"noreferrer noopener\" title=\"RJ45 Cables\">RJ45 Cables<\/a><\/figcaption><\/figure><\/div>\n\n\n\n<p>MISUMI offers both Single Layer Shielded and Double Layer Shielded RJ45 cables, which can be selected according to your environment as well as a choice of lengths from 0.1 meter to 100 meters of cable, in 0.05 meter increments for lengths up to 20 meters, and in 0.1 meter increments for longer lengths. Explore the selection <a href=\"https:\/\/us.misumi-ec.com\/vona2\/el_wire\/E1424000000\/E1424010000\/\" target=\"_blank\" rel=\"noreferrer noopener\">here<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Very commonly used in homes and offices, RJ45 cables are probably one of the most familiar cables to you. However, many of you may be puzzled by words such as Cat5e, Cat6A, UTP, and STP that you do not often hear when you try to select them. In this article, I will show you how to choose the right RJ45 [&hellip;]<\/p>\n","protected":false},"author":66,"featured_media":11020,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false},"categories":[1137],"tags":[794,816,842,1189,401,1191,1190,1188],"aioseo_notices":[],"gutentor_comment":0,"_links":{"self":[{"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/posts\/11016"}],"collection":[{"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/users\/66"}],"replies":[{"embeddable":true,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/comments?post=11016"}],"version-history":[{"count":1,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/posts\/11016\/revisions"}],"predecessor-version":[{"id":11021,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/posts\/11016\/revisions\/11021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/media\/11020"}],"wp:attachment":[{"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/media?parent=11016"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/categories?post=11016"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/us.misumi-ec.com\/blog\/wp-json\/wp\/v2\/tags?post=11016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}