• MISUMI is open to support you, but some lead times may be impacted. Read more about our COVID 19 Response

TH-T Series Thermal Relay (Mitsubishi Electric Automation)

TH-T Series Thermal Relay (Mitsubishi Electric Automation)

Mitsubishi thermal relay TH-T series.
[Features]
・ Incredible performance housed in a small body.
・ The highly advanced version of the Mitsubishi Electric electromagnetic opening/closing device.
・ Can be used to detect motor overload and locked rotor current.
・ Product lineup containing overload short circuit protection, time lag and accelerated types for every application.
[Applications]
・ Motor burnout protection.

Edit Part Configuration

Part Number

Configure to get your Part Number

Part Number
TH-T18 0.7A
TH-T18 1.7A
TH-T25BCKP 1.3A
TH-T25BCKP 1.7A
TH-T25BCKP 2.1A
TH-T25BCKP 2.5A
TH-T25BCKP 3.6A
TH-T25BCKP 5A
TH-T25BCKP 6.6A
TH-T25BCKP 9A
TH-T25BCKP 11A
TH-T25BCKP 15A
TH-T25BCKP 22A
TH-T25KP 0.7A
TH-T25KP 0.9A
TH-T65KP 54A
TH-T100KP 67A
Part NumberVolume DiscountDays to Ship RoHSDimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Specifications Frame size Finger protection/terminal cover Nominal heater size
(A)
Settling current adjustment range
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V
(A)
Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V
(A)
Application Terminal screw size (main circuit/operating circuit) Trip class Trip free Reset method Operation display (lever display) Manual trip check

10 Days

6554576.5Standard/2 elementsT18Standard Equipment0.70.55 to 0.852/22/21/10.3/0.30.5For electromagnetic opening/closing deviceM3.5/M3.510AStandard EquipmentManual / automatic switching allowedStandard EquipmentStandard Equipment

10 Days

6554576.5Standard/2 elementsT18Standard Equipment1.71.4–22/22/21/10.3/0.30.5For electromagnetic opening/closing deviceM3.5/M3.510AStandard EquipmentManual / automatic switching allowedStandard EquipmentStandard Equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal1.31 to 1.62/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal1.71.4 to 22/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal2.11.7 to 2.52/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal2.52 to 32/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal3.62.8 to 4.42/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal54 to 62/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal6.65.2 to 82/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal97 to 112/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal119 to 132/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal1512 to 182/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25With wire rationalizing terminal2218 to 262/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25Standard equipment0.70.55 to 0.852/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-5163793 elements (2E)T25Standard equipment0.90.7 to 1.12/32/31/20.3/0.31For electromagnetic switchesM4/M3.510 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-578983.53 elements (2E)T65NA5443 to 652/32/31/20.5/11For electromagnetic switchesM6/M410 AStandard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

4 Days

-73.58983.53 elements (2E)T100NA6754 to 802/32/31/20.5/11For electromagnetic switchesM6/M410Standard equipmentManual / automatic switching allowedStandard equipmentStandard equipment

Loading...

  1. 1

Basic Information

Auxiliary contact 1a1b Rated insulation voltage(V) 690 Rate Impulse voltage resistant(kV) 6
Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V(A) 0.2 Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V(A) 0.1

Additional Products in this Category