Coiled Cords

A coiled cord is a cord that is curled in a spiral shape that extends and retracts. It is also called a spring cable and is used in a wide range of applications because it is freely extendable. This is used for the power supply or signals of equipment that requires extending, such as electric tools or devices with adjustable height; for the remote control connection of power lifts; or in situations that require spring properties, such as movable sensors or cameras. Flex-resistant types are available for built-in cables. A coiled cord with a magnet installed at the power strip can be attached to a desk or machine with the magnet. This enables installation where it is easy to use and the cable can be laid out through the coil in an organized way. The coiled cord that integrates the air pressure polyurethane tube with the electric signal cable can be used in the same line as the air and electricity.

5 items

Hide Filters  XFilter Results
  1. 1
Days to Ship
  • All
  • Same Day
  • 4 Days or Less
  • 5 Days or Less
  • 7 Days or Less
Brand
Product Series
Days to Ship
Specifications
Total length(m)
Conductor cross section(mm2)
AWG size(AWG)
Number of cores(Core)
Rated voltage
Shield
Properties
Representative standards
Sheath (outer coating) material
Insulation body materials

    100V or Less

    • New Products

    30V 300V Coiled Cable

      300/30V UL Standard

        150V Pneumatic Tube Integrated Model (MISUMI)

          300V PSE Compliant (MISUMI)

          Brand

          MISUMI

          MISUMI

          MISUMI

          MISUMI

          MISUMI

          Product Series

          100V or Less

          30V 300V Coiled Cable

          300/30V UL Standard

          150V Pneumatic Tube Integrated Model (MISUMI)

          300V PSE Compliant (MISUMI)

          Days to Ship 4 Days 4 Days Same Day

          Stock Items Included

          7 Days 4 Days
          Specifications
          • Conductor consists of 2 or more pieces of strand wire
          • Conductor is thinned
          • Rated Voltage Less than 100 V
          • Suitable for power supply
          • Suitable for signal
          • Excellent in flex-resistance
          • Conductor consists of 2 or more pieces of strand wire
          • Rated Voltage 30 V
          • Rated Voltage 300 V
          • Passed the vertical flame test by UL standards
          • Compliant with UL Appliance Wiring Material
          • Conductor consists of 2 or more pieces of strand wire
          • Excellent in flex-resistance
          • Conductor consists of 2 or more pieces of strand wire
          • Rated Voltage 150 V
          • Meets the standards defined by Electrical Appliance and Material Safety Law (PSE)
          • Suitable for power supply
          • Suitable for signal
          • Excellent in flex-resistance
          • Conductor consists of 2 or more pieces of strand wire
          • Rated Voltage 300 V
          Total length(m)0.3 ~ 10.3 ~ 0.520.305 ~ 0.910.2 ~ 0.731 ~ 3
          Conductor cross section(mm2)0.3 ~ 20.3 ~ 0.50.08 ~ 0.250.2 ~ 0.30.75 ~ 2
          AWG size(AWG)14 ~ 2220 ~ 2223 ~ 2823 ~ 2514 ~ 18
          Number of cores(Core)2 ~ 162 ~ 162 ~ 752 ~ 4
          Rated voltageLow current circuits300V / Low current circuits300V / Low current circuitsLow current circuits300V
          ShieldNoneNoneNoneNoneNone
          PropertiesAbrasion resistance----
          Representative standards--UL-PSE
          Sheath (outer coating) materialUrethane-basedUrethane-basedPVCUrethane-basedPVC
          Insulation body materials-FluorinePVC / Polyethylene typeFluorinePVC