Water and Steam Valve and Hose Images

Viscosity of Water – Dynamic & Kinematic | Table

This table lists dynamic viscosity (resistance to shear) and kinematic viscosity (dynamic viscosity divided by density) for water across temperature, so you can quickly grab the right value for Reynolds number checks and fluid-flow calculations.

Viscosity by Degree Celsius

Water Viscosity Table
Water Conditions Water Dynamic Viscosity Water Kinematic Viscosity
Water Temperature°C Water Vapor PressureMPa Dynamic ViscosityPa·s / N·s/m² Water ViscositycP / mPa·s Dynamic Viscositylbf·s/ft² ×10⁻⁵ Kinematic Viscositymm²/s / cSt
10.0006540.00174331.74333.64091.7437
50.0008570.001548941.548943.2351.5494
100.00120.0013061.30602.72761.3065
150.00170.00115381.15382.40971.155
200.00230.00100161.00162.09191.0035
250.00320.000890040.890041.85890.8927
300.00420.000797220.797221.66500.8007
350.00560.000724970.724971.51410.7293
400.00740.000652720.652721.36320.6579
450.00960.000599610.599611.25230.6055
500.01240.000546500.546501.14140.5531
550.01570.000506260.506261.05740.5135
600.01990.000466020.466020.97330.4740
650.0250.000434780.434780.9080.4434
700.03120.000403530.403530.84280.4127
750.03860.000378780.378780.79110.3885
800.04740.000354040.354040.73940.3643
850.05770.000334110.334110.69780.3449
900.07020.000314170.314170.65620.3255
950.08460.000297880.297880.62220.3096
1000.1010.000281580.281580.58810.2938
1200.1990.000232030.232030.48460.2460
1400.3620.000196640.196640.41070.2123
1600.6180.000170430.170430.35590.1878
1801.0000.000150380.150380.31410.1695
2001.5500.000134580.134580.28110.1556
2202.3200.000121770.121770.25430.1449
2403.3500.000111060.111060.23200.1365
2604.6900.000101810.101810.21260.1299
2806.4200.000093550.093550.19540.1247
3008.5900.000085860.085860.17930.1206
32011.300.000078310.078310.16360.1174
34014.600.000070330.070330.14690.1152
36018.700.000060310.060310.12600.1143
38023.950.000050290.050290.10510.1134
40030.680.000040270.040270.08420.1125

Viscosity by Degree Fahrenheit

Water Viscosity Table
Water Conditions Water Dynamic Viscosity Water Kinematic Viscosity
Water Temperature°F Water Vapor PressureMPa Dynamic ViscosityPa·s / N·s/m² Water ViscositycP / mPa·s Dynamic Viscositylbf·s/ft² ×10⁻⁵ Kinematic Viscositymm²/s / cSt
320.0006120.00179191.79193.74241.7923
370.0007380.00165691.65693.46051.6573
420.0008890.00152191.52193.17861.5224
470.00110.0013871.38702.89671.3875
520.00130.00127221.27222.65701.2728
570.00170.00115731.15732.41721.1579
620.00200.00104251.04252.17751.0432
670.00240.00092770.927701.93770.9285
720.00290.00088820.888161.85530.8908
770.00370.00083660.836611.74760.8402
820.00470.00078490.784911.63990.7895
870.00580.00073320.733221.53220.7388
920.00720.00068150.681521.42450.6881
970.00880.00062980.629821.31680.6374
1000.00650.00068480.684831.43170.6894
1200.01410.00052600.526021.09990.5330
1400.02800.00041550.415470.86910.4244
1600.05120.00033990.339930.71090.3509
1800.08760.00029260.292630.61190.3045
2000.14170.00025780.257770.53920.2701
2200.1180.00026960.269590.56380.2818
2400.2760.00021190.211850.44290.2260
2600.5090.00017970.179740.37560.1950
2800.8310.00015920.159200.33280.1753
3001.2530.00014450.144480.30210.1612
3201.7830.00013330.133300.27870.1504
3402.4310.00012450.124470.26020.1421
3603.2050.00011730.117280.24520.1354
3804.1130.00011130.111260.23260.1299
4005.1640.00010620.106200.22200.1255
4206.3640.00010180.101840.21290.1219
4407.7140.000097930.097930.20470.1188
4609.2230.000094360.094360.19730.1160
48010.900.000091010.091010.19020.1135
50012.740.000087830.087830.18360.1112
52014.750.000084800.084800.17730.1091
54016.930.000081910.081910.17130.1072
5607.7950.000088420.088420.18470.1220
5809.1300.000084180.084180.17580.1199
60010.630.000079990.079990.16710.1181

MISUMI USA carries a wide range of industrial manufacturing components – including Safety and Control Valves, and Hoses – for your next project or machine fix. If you have any questions about measurement or sizing for your hose, valve, or pipe needs, feel free to connect with our product experts, and engineers. Also, if you are looking for more insights be sure to check out our other blog articles, including: Specific Heat Capacity of WaterWater Density vs Temperature and Pressure, and more.

AuthorScott Bredemann | Updated: 2/20/2026

Disclaimer:
The content on this webpage is for informational purposes only. MISUMI makes no guarantees, expressed or implied, regarding the accuracy, completeness, or validity of the information. Performance parameters, tolerances, designs, materials, or processes should not be assumed to reflect third-party suppliers’ or manufacturers’ deliverables within MISUMI’s network. Buyers are responsible for specifying their part requirements.